AmpleVolts Product Information
Advantages of the AmpleVolts program
AmpleVolts is a software program designed to fill a need in the industry to save time in downloading critical and accurate electrical information from electrical and electronic equipment. As much as 70% of time is saved when using this program with certain testing techniques.
The program has an Activation Code protection for peace of mind for security of your work and confidentiality of your customers.
Tolerances of both AC and DC functions is variable this enables exact tolerance settings of known equipment.
Power usage of equipment can be calculated with a simple push of a button. AC & DC equipment, both 3 phase and single phase equipment, and a combination of both can be tested.
All measurements, waveforms and graphs are detected by an Oscilloscope only a few manually inputted measurements are used.
All data acquisition pages have a Control Setup / settings area for the Oscilloscope command, Comments Section and Test Complete Function.
Data can be transferred to pdf. format within seconds, Prior test file can be recalled when testing the same equipment, completing client and unit details.
Commercial details can be reused for the same customer on different equipment.
Downloaded information saves time in generating long labour intensive reports comprising of text, graphs, waveform into pdf. formats.
This program is easy to use and follow, going systematically through the Common Field Area Test Complete Indicators.
Out of tolerance Indicators for measurements not complying with specification flagged in the summary page settings.
Pages to be printed can be either deselected or selected as required.
Invoices can be printed from this document if required.
Screen Descriptions
Common Field Area The Common Field Area consists of two indicators, the first indicator to show whether or not a server connection has been established when it has been established the indicator will be illuminated. The second indicator is to show when the Scopemeter has been established a connection the indicator will also illuminate. In addition to this when the Test complete button on each data aquisition page is enabled the corresponding tab will change colour to show this page is completed.
Summary Page
The summary page comprises of a number of Commercial fields with the following headings, Customer Details, Work Details, Test Dates and testing Personnel Details.
Buttons to carry out the follow functions are, Load Previous Sessions, Saving this Session and Quit. In addition to this there is an area for listing of part to be replace or having been replaced.
Admin
The Administrative page comprises of the Status of Purchased Credits detailing remaining activations. Also within this screen The pages to be printed can be selected, The type of report to be generated - Installation, Commissioning or Service. The Company header can be added to the program for printing on the final report. The destination folder of the finalized Report can be selected. A charges section is there for direct Invoicing to the customer within the report or forwarding to the accounts department for processing Finally printing of the report can be Generated within seconds to form a perfect PDF. saved Document.
Setup Page
Within this screen buttons are located in the Comms area for redetecting the server and Scopemeter if connection is lost. The remainder of this page is dedicated to the setup of the functions required for selection of Input and Output types. This comprises of upto 2 input supplies and can be of either AC or DC in any combination. 1 only output function applies but can be either AC or DC. Also on this page are the settings required for Power rating of the equipment, THD, Frequency, Current. and Battery parameters.
Commissioning The Commissioning page comprises of a series of radial buttons which allows for answers to be given in the form of Ok, Not Ok, and N/A answers and individual comments area. It is also divided into sections, Electrical, Equipment and Battery Installations with a comments section and Test Complete Button.
Visual Checks
The Visual Checks page comprises of a series of radial buttons which allows for answers to be given in the form of Ok, Not Ok, and N/A answers. It is divided into sections, Visual/Mechanical Inspection, Batteries/Environment Visual Checks Comments section and Test Complete Button.
General Service
The General Service page consists of the following sections. They are - Installation & Diagnostics, Functions & Performance, Service Review, General Service Comments section and Test Complete Button.
Mains 1 AC Voltage
The Mains 1 Voltage page enables, once the probe choice settings are setup, recording of Voltage, Frequency and Total Harmonic Distortion in measurement, waveform and graph form. Also present is a section for Mains 1 Comments and a Test Complete Button.
Mains 1 DC Voltage
The Mains 1 DC Voltage page enables, once the probe choice settings are setup, recording Voltage, Frequency and Total Harmonics Distortion in measurement, waveform and graph form. Also present is a Mains 1 DC Voltage Comments section and Test Complete Button.
Mains 2 AC Voltage
The Mains 2 Voltage page enables, once the probe choice settings are setup, recording ofVoltage, Frequency and Total Harmonic Distortion in measurement, waveform and graph form. Also present is a section for Mains 2 Voltage Comments and a Test Complete Button.
Mains 2 DC Voltage
The Mains 2 DC Voltage page enables, once the probe choice settings are setup, recording Voltage. Frequency and Total Harmonics Distortion in measurement, waveform and graph form. Also present is a section for Mains 2 DC Voltage Comments section and Test Complete Button.
Output AC Voltage
The Output Voltage page enables, once the probe choice settings are setup, recording Voltage, Frequency and Total Harmonic Distortion in measurement, waveform and graph form Neutral to Earth reading. Also present is a section for Output Voltage Comments and a Test Complete Button.
Output DC Voltage
The Output DC Voltage page enables, once the probe choice settings are setup, recording Voltage, Frequency and Total Harmonic Distortion in measurement, waveform and graph form. Also present is a section for Output DC Voltage Comments section and Test Complete Button.
Charger Voltage
The charger voltage page enables, once the probe choice settings are setup, recording a charger voltage and the entering of Battery details. Also present is a Charger Voltage Comments section and Test Complete Button.
Mains 1 AC Current
The Mains 1 Current page enables, once the probe choice settings are setup recording the following information Current (rms), Crest Factor, Total Harmonic Distortion in measurement, actual Waveform and Graph form on selected phases including Neutral. Also present is a section for AC Mains 1 Current Comments and Test Complete Button.
Mains 1 DC Current
The Mains 1 DC Current page enables, once the probe choice settings are setup, recording the Mains 1 DC current. The Current waveform and Harmonics Distortion graph are also recorded. Also present is a Mains 1 DC Current Comments section and Test Complete Button.
Mains 2 AC Current
The Mains 2 Current page enables, once the probe choice settings are setup, recording the following information Current (rms), Crest Factor, Total Harmonic Distortion in measurement, actual Waveform and Graph form on selected phases including Neutral. Also present is a section for AC Mains 2 Current Comments and Test Complete Button.
Mains 2 DC Current The Mains 2 DC Current page enables, once the probe choice settings are setup, recording the Mains 2 DC Current. The Current waveform and Harmonic Distortion graph are also recorded. Also present is a Mains 2 Comments section and Test Complete Button.·
Output AC Current
The Output Current page enables, once the probe choice settings are setup, recording the following information Current (rms), Current (peak), Crest Factor, Total Harmonic Distortion in measurement, actual Waveform and Graph form on selected phases including Neutral. Also present is a section for Output Current Comments and Test Complete Button.
Output DC Current
The Output DC Current page enables, once the probe choice settings are setup, recording the Output DC Current. The Current waveform and Harmonics Distortion graph are also recorded. Also present is a Output DC Current Comments section and Test Complete Button.
Output Power
The Output power page enables, once the probe choice settings on the Oscilloscope channels are setup, recording the following measurements - Real Power, Apparent Power, Power Factor and Load Percentage can be taken. Also present is a section for the Waveforms for Voltage and Current, Output Power Comments and Test Complete Button.
Battery Voltages
The Battery Voltage page enables, once the probe choice settings have been established the recording of the following information - Battery Settings, Battery Information, Acquiring of Battery Readings for upto four strings of Batteries (individually, in rows or combination of both or all Batteries), Battery Comments and Test Complete Button.
Discharge Curve
The Discharge Curve page enables, once probe choice settings have been established for a recorded graph of up to 2 strings of batteries at any one time for a manually set period of time. Also present are sections for Manual Measurements, Stop Test Function, Discharge Curve Comments and Test Complete Button.